Hyundai Accent

Repair and car operation



Hyundai Accent
+ 1. The maintenance instruction
+ 2. The engine
+ 3. Greasing system
+ 4. Cooling system
+ 5. The control, toxicity decrease
+ 6. Fuel system
+ 7. Ignition system
+ 8. Coupling
+ 9. A transmission
+ 10. Axes and power shafts
+ 11. A suspension bracket
+ 12. A steering
+ 13. Brake system
+ 14. A body
+ 15. A central air
- 16. The electric equipment
   16.1. Specifications
   16.2. Electric chains
   16.3. Gymnastics system
   16.4. Check of an electric chain of gymnastics
   16.5. Power failure check on a wire connecting the storage battery with the generator
   16.6. Check of the current developed by the generator
   16.7. Check of developed pressure
   16.8. The generator
   16.9. The storage battery
   16.10. Check of relative density of electrolit
   16.11. Gymnastics of the storage battery
   16.12. Survey of the storage battery
   16.13. Start system
   16.14. A starter
   16.15. Check and replacement of elements статора
   16.16. The switch of blocking of ignition
   16.17. Check of the relay of a starter
   16.18. Check of the switch of blocking of ignition
   16.19. A radio receiver
   16.20. Dynamics
   16.21. The aerial
   16.22. The multipurpose switch
   16.23. A sound signal
   16.24. Safety locks
   16.25. A combination of devices
   16.26. The engine of a screen wiper of a windscreen
   16.27. Replacement of a headlight and the forward index of turn
   16.28. Adjustment of light of headlights
+ 17. The appendix
+ 18. Electroschemes




16.6. Check of the current developed by the generator

This check allows to define, whether develops the generator a current which is equivalent to rated power.

Preparation for check

PERFORMANCE ORDER
1. Before test check up following elements:

– A condition of the storage battery established in the car;
– A tension of a belt of a drive of the generator.

The prevention

The storage battery which is used for check of the current developed by the generator, should be partially discharged. At completely charged батаре check cannot be executed because of insufficient loading of the generator.


2. Include ignition.
3. Disconnect a wire from the negative plug of the storage battery.
4. Disconnect a wire from generator plug "B".
5. Connect the ampermeter of a direct current with a limit of measurement 0–100 A consistently between plug "B" and the wire disconnected from the generator. Be convinced, that negative щуп the ampermeter have connected to the wire disconnected from the generator.

The prevention

Connect wires and щупы the ampermeter very reliably as on a chain the big current will proceed.


6. Connect the voltmeter (0-20) between plug "B" of the generator and "weight". Be convinced, that positive щуп the voltmeter have connected to generator plug "B".
7. Connect a tachometre and a wire to the negative plug of the storage battery.
8. Leave a cowl opened.

Check

PERFORMANCE ORDER
1. Check up, that the voltmeter scale is well visible for definition of size of pressure. If the voltmeter shows pressure 0 In, means, the electric chain connecting plug "B" of the generator and the negative plug of the storage battery is not closed, the fusible insert or unreliable connection with "weight" has fused.
2. Start the engine and include headlights.
3. Include a headlight of headlights and the heater fan in a mode of the maximum giving of air. Quickly increase frequency of rotation of a cranked shaft of the engine to 2 500 mines-1 and read values on devices, thus the ampermeter will show a current developed by the generator.

The prevention

After start of the engine the current of gymnastics of the storage battery very quickly decreases, therefore this check is necessary for carrying out very quickly.



Result of check

PERFORMANCE ORDER
1. Ampermeter indications should exceed limiting value. If value of a current less than limiting value, and a wire connecting an exit of the generator, as it should be, remove the generator from the car and check up it.

Limiting value of a current:
52,5 And for the generator 75 And
63,0 And for the generator 90 And


The prevention

Limiting value of a current is specified on the tablet attached to the case of the generator.
The current developed by the generator, depends on temperature and loading. Therefore for reception of limiting value of a current partially discharge the storage battery, preliminary having included headlights on the car with the idle engine.
Limiting value of a current developed by the generator cannot be received, if generator or air temperature too high.


2. After end of test of limiting value of the current developed by the generator, translate the engine in a mode of idling and switch off ignition.
3. Disconnect a wire from the negative plug of the storage battery.
4. Remove a tachometre, the voltmeter and the ampermeter.
5. Connect a wire to generator plug "B".
6. Connect a wire to the negative plug of the storage battery.